SGE Capillary Columns
5% Phenyl Polysilphenylene-siloxane- Column Type BPX5
ID (mm)
|
Length (m) |
Film Thickness (mµ) |
Temperature Limits (C°) |
Part No.
|
0.10 |
10 |
0.10 |
-40 to 360/370 |
054099 |
0.15 |
10 |
1.20 |
-40 to 360/370 |
054106 |
12 |
0.25 |
-40 to 360/370 |
054103 |
12 |
0.40 |
-40 to 360/370 |
054107 |
25 |
0.25 |
-40 to 360/370 |
054104 |
25 |
0.40 |
-40 to 360/370 |
054108 |
30 |
0.15 |
-40 to 360/370 |
054110 |
50 |
0.25 |
-40 to 360/370 |
054105 |
0.22 |
12 |
0.25 |
-40 to 360/370 |
054112 |
25 |
0.25 |
-40 to 360/370 |
054113 |
25 |
1.00 |
-40 to 360/370 |
054116 |
30 |
0.25 |
-40 to 360/370 |
054142 |
50 |
0.25 |
-40 to 360/370 |
054114 |
50 |
1.00 |
-40 to 360/370 |
054117 |
0.25 |
15 |
0.25 |
-40 to 360/370 |
054100 |
15 |
1.00 |
-40 to 360/370 |
054121 |
30 |
0.25 |
-40 to 360/370 |
054101 |
30 |
0.50 |
-40 to 360/370 |
0541025 |
30 |
1.00 |
-40 to 360/370 |
054122 |
60 |
0.25 |
-40 to 360/370 |
054102 |
60 |
1.00 |
-40 to 360/370 |
054123 |
0.32 |
6 |
1.00 |
-40 to 360/370 |
0541261 |
12 |
0.25 |
-40 to 360/370 |
054118 |
12 |
0.50 |
-40 to 360/370 |
054124 |
12 |
1.00 |
-40 to 360/370 |
054127 |
15 |
0.25 |
-40 to 360/370 |
054144 |
15 |
1.00 |
-40 to 360/370 |
054152 |
25 |
0.25 |
-40 to 360/370 |
054119 |
25 |
0.50 |
-40 to 360/370 |
054125 |
25 |
1.00 |
-40 to 360/370 |
054128 |
25 |
3.00 |
-40 to 350/360 |
054136 |
30 |
0.25 |
-40 to 360/370 |
054145 |
30 |
0.50 |
-40 to 360/370 |
0541205 |
30 |
1.00 |
-40 to 360/370 |
054153 |
50 |
0.25 |
-40 to 360/370 |
054120 |
50 |
0.50 |
-40 to 360/370 |
054126 |
50 |
1.00 |
-40 to 360/370 |
054129 |
60 |
0.25 |
-40 to 360/370 |
054146 |
60 |
1.00 |
-40 to 360/370 |
054154 |
0.53 |
12 |
0.25 |
-40 to 360/370 |
054133 |
12 |
1.00 |
-40 to 360/370 |
054130 |
12 |
3.00 |
-40 to 350/360 |
054138 |
>
15 |
0.50 |
-40 to 360/370 |
0541344 |
15 |
1.00 |
-40 to 360/370 |
054147 |
15 |
1.50 |
-40 to 350/360 |
0541347 |
15 |
3.00 |
-40 to 350/360 |
054159 |
25 |
0.25 |
-40 to 360/370 |
054134 |
25 |
1.00 |
-40 to 360/370 |
054131 |
25 |
3.00 |
-40 to 350/360 |
054139 |
30 |
0.50 |
-40 to 360/370 |
0541345 |
30 |
1.00 |
-40 to 360/370 |
054148 |
30 |
1.50 |
-40 to 350/360 |
0541348 |
30 |
3.00 |
-40 to 360/370 |
054160 |
50 |
1.00 |
-40 to 360/370 |
054132 |
60 |
1.00 |
-40 to 360/370 |
054158 |
BPX5 Capillary Columns
* Very low bleed- Ideal for trace analysis
* Maximum temperature 370°C
* Extremely Inert
* Ideal for GC-MS
* Suitable Upgrade from DB-5, DB-5ms, HP-5, Ultra-2, Rtx®-5, Rtx-5Sil MS, Rtx-5MS, AT-5, AT-5MS, 007-5MS, SPB-5, CP-Sil 8CB, VF-5ms, RSL-200, CB-5,OV®-5, PE-5, 007-2(MPS-5), SE-52, SE-54, XT1-5, PTE-5, CC-5, RH-5ms & ZB-5