SGE Ferrules for Capillary Columns- Thermo Finnigan
•15% Graphite / 85% Vespel Ferrules
•100% Graphite Ferrules
•SilTite™ Metal Ferrules
•Replacement SilTite™ Metal Ferrules
•Replacement SilTite™ Nuts
•Replacement SilTite™ Basic Seals
•Butt & Ferrule Kit
15% Graphite / 85% Vespel Ferrules- For all Injectors & Detectors (Not for 8000 Series & Trace GC)
Column ID |
Ferrule ID |
Pack Size |
Part No |
0.1- 0.25mm |
0.4mm |
10 |
SG0726549 |
0.32mm |
0.5mm |
10 |
SG0726557 |
0.53mm |
0.8mm |
10 |
SG0726548 |
1/8" OD Packed Columns |
1/8" |
10 |
SG072669 |
1/4" OD Packed Columns |
1/4" |
10 |
SG072667 |
15% Graphite / 85% Vespel Ferrules- For all Trace Injectors & Detectors at atmospheric pressure e.g. FID
Column ID |
Ferrule ID |
Pack Size |
Part No |
0.1-0.25mm |
0.4mm |
10# |
SG072696 |
0.32mm |
0.5mm |
10# |
SG072697 |
0.53mm |
0.8mm |
10# |
SG072698 |
# To be used in combination with brass nut (Part No. G1034085)
15% Graphite / 85% Vespel Ferrules- Brass Nut for Trace GC Injectors & Non - MS Detectors
Pack Size |
Part No |
2 |
SG1034085 |
100% Graphite Ferrules- Injectors & Detectors at atmospheric pressure e.g. FID (Not for GC-MS)
Column ID |
Ferrule ID |
Pack Size |
Part No |
0.1- 0.32mm |
0.5mm |
10 |
SG072619 |
0.45- 0.53mm |
0.8mm |
10 |
SG072614 |
for 1/8" OD Packed Columns |
1/8" |
10 |
SG072622 |
for 1/4" OD Packed Columns |
1/4" |
10 |
SG072621 |
SilTite™ Metal Ferrules- For all Injectors & Detectors- Including GC-MS (starter Kit)
(SilTite™ information)
Column ID |
Ferrule ID |
Pack Size |
Part No |
0.1- 0.25mm |
0.4mm |
10* |
SG073450 |
0.32mm |
0.5mm |
10* |
SG073451 |
0.53mm |
0.8mm |
10* |
SG073452 |
* Includes 10 ferrules, 2 SilTite™ nuts
Replacement SilTite™ Metal Ferrules For all Injectors & Detectors- including GC-MS
(SilTite™ information)
Column ID |
Ferrule ID |
Pack Size |
Part No |
0.1- 0.25mm |
0.4mm |
10 |
SG073220 |
0.32mm |
0.5mm |
10 |
SG073221 |
0.53mm |
0.8mm |
10 |
SG073222 |
Butt & Ferrule Kit
Packed to Capillary Column Conversion Butt & Ferrule Kit- For Thermo Finnigan & Fisons 8000 Series GC
Column ID |
Pack Size |
Part No |
0.1- 0.53mm |
10 |
SG0103436 |
Why Choose SilTite™ Ferrules?
• No more leaks
• No need to re-tighten nut after installation and thermal cycling
• Have the same thermal expansion coefficient as SilTite nuts thus giving a highly reliable seal
• Reusable nut
.
How to use SilTite™ ferrules?
• Only use the special SilTite nut with a SilTite ferrule
• For Agilent Technologies inlet connections, only use with SilTite inlet base seal and SilTite nut